CIRCOR Product Catalog: Allweiler Norway
Series NT
![]() | Volute Casing Centrifugal Pump in base plate design up to PN 10
|
Pumped Liquid
Pure water, industrial water, sea water, condensate, oils, brines, lyes, hot water. The liquids to be pumped must not contain any abrasive particles nor chemically attack the construction materials of the pump.
Main Fields Of Application
Cooling and heating circulating systems, water treatment, desalinization, dust separation and spray-coat plants, air conditioning, cooling, swimming pool and industrial techniques
Download files for series NT
GP_NT_GB.pdf (61,62 KB)
Performance Data NT
| Capacity | Q | up to | 2300 | m3/h |
| Delivery Head | H | up to | 145 | m |
| Discharge Pressure | pd | up to | 10/16 | bar |
| Fluid Temperature | t | up to | 140 | °C |
Construction features
Casing dimension and rated output acc. to DIN EN 733/EN 733
Base plate design (pump and motor mounted on a base plate)
Dry installation
Horizontal installation
Bearing bracket design
Spacer coupling (optional)
2-stage pump type at defined sizes